Gold APP Instruments Corp. China Introduction: Fully automated BET particle surface area analyzer...
Gold APP Instruments Corp. China Introduction: Fully automated BET particle surface area analyzer...: F-Sorb 2400CE BET surface area analyzer introduction F-Sorb X400CE series surface area and porosity analyzers are new generation ins...
Tuesday, November 5, 2013
langmuir specific surface area analysis equipment
V-Sorb 2800S surface area analyzer introduction
V-Sorb 2800S is researched and developed by Gold APP Instruments
for single and multi-point BET surface area, also with Langmuir surface area
and others related with SSA by using static volumetric principle. Compared with
other companies’ analyzers, multi pioneered techs make it’s performance much
better, heighten accuracy and consistence of results, enhance measurement
stability, all these lead to a leading level in international competitors.
Products designed from the user perspective and equipped with fully automated
operation, user-friendly interface makes it easy to learn, imported accessories
assure stability and prolong life. Perfect design, sophisticated production and
strict testing guarantee to meet customers’ real demands. High cost performance
of V-Sorb 2800S easily ensure your investment profits and flexible equipped
peripheral can satisfy different users’ requests.
V-Sorb 2800S surface area analyzer parameters
Analysis Method: static volumetric nitrogen adsorption principle
Versatility: Adsorption and desorption isotherms, Single and multi-point
BET surface area, Average particle diameter estimation, t-plot external surface
area, True density analysis, Langmuir surface area, carbon black (STSA),
adsorption constant C.
Measuring Ranges: 0.01m2/g to no known upper limit (surface
area)
Accuracy: repeatability errors ≤1%
Vacuum System: V-Sorb unique monolithic manifolds and solenoid valve
control system, greatly reduce the dead volume; improve the adsorbate
micro-change sensitivity; enhance pore size distribution analysis resolution;
decrease connecting points; strengthen sealing performance and prolonged
instrument life
Coolant Level Prober: V-Sorb original coolant level control system with
temperature probe, ensure the coolant level unchanged when compares with sample
cells in the whole analysis process, completely eliminate the analysis errors
caused by dead volume change
Sample Treatment: the whole treatment procedures are controlled by
dedicated software, as well with a start time preset function which can realize
unattended operation at night
Control System: programmable solenoid valve system with high integration
and strong anti-interference ability, enhance instrument’s stability and life
Sample Ports: two samples’ analyzing and two samples’ degassing
concurrently
Pressure Measurement: imported sectional measuring dual pressure transducer,
notably improve the measuring accuracy at low P/Po point, 0-1000Torr
(0-133Kpa), 0-10Torr (0-1.33Kpa)
Transducer Accuracy: imported silicon thin film pressure transducer, accuracy
can reach 0.1% of real reading, better than 0.1% of F.S.(full-scale), far
accurate than Pirani resistance vacuum gauge(general error is 10%-15%)
Partial Pressure: P/Po controllable accuracy range is 5x10-6-0.998
Ultimate Vacuum: 4x10-2Pa (3x10-4 Torr)
Vacuum Pump: built-in bipolar vacuum pump controlled by patented
software which can auto control pump’s start/stop
Adsorbate Gas: high purity nitrogen (≥99.999%), Ar, Kr, CO, C02, C4H10
etc. non-corrosive gases are optional
Data Acquisition: high-precision and high integration data acquisition
modules, minimal error, strong anti-interference ability
Data Reduction: Windows®-based independent developed Gold APP softwareTM,
perfect versatility, produced full featured and multi-model reports
V-Sorb 2800S surface area analyzer features
A: Vacuum System
1. Unique integral manifolds system, decrease connecting
points apparently, reduce leak rate, improve ultimate vacuum.
2. Modularity design can configure as customer requests,
benefits future functions extension and instrument maintenance.
3. Germany
imported bipolar vacuum pump, low noise, stable working, oil-return prevention;
ultimate vacuum can reach 4x10-2Pa (3x10-4Torr).
B: Control System
1. Industry used programmable solenoid valve system,
strong anti-interference ability, convenient for installation and
uninstallation.
2. Separated analysis and treatment manifolds can prevent
foreign matter to contaminate manifolds in sample treatment.
C. Measures for Improving
Accuracy
1. Imported silicon thin film capacitive pressure transducer,
accuracy can reach 0.1% of real reading, better than 0.1% of F.S. (full-scale).
2. 0-10Torr (optional) and 0-1000Torr dual pressure transducers,
sectional measurement in pressure range can reduce errors in low vacuum,
0-10Torr silicon thin film transducer is highly accurate than Pirani resistance
vacuum gauge (general error is 10%-15%).
3. Unique monolithic manifolds system, decrease connecting
points and reduce leak rate apparently.
4. Original stepping coolant level control system, ensure
the coolant level unchanged when compares with sample cells in the whole
analysis process, completely eliminate the analysis errors caused by dead volume
change.
5. Pioneered gas outlet and inlet control system can
efficiently prevent sample splash in evacuation and gas inlet process,
guarantee clean manifolds and sample weight unchanged, avoid zero and liner
drifting caused by transducer’s macro-change.
D. Data Acquisition and
Reduction
1. High precision and integration data acquisition module
is easy to connect, minimal errors and strong anti-interference ability;
standard 485 communication mode is good for analyzer’s applications extension
and interconnection, can also conveniently switched to RS232 and USB modes.
2. Multi calculating methods for data reduction provides
all-round sample analysis options; powerful data archiving and searching system
helps a lot for data management.
V-Sorb 2800S surface area analyzer application
1. Super micro powder, nanomaterials, particle and fiber
shaped surface area analysis.
2. Product quality control for powder materials related
corporations.
3. Research institutes, universities for BET theory
teaching.
4. Fuel cells, catalysts, additives, adsorbent, ceramics,
magnetic materials, energy storage materials etc.
5. Other researches concern surface area performance.
Contact info:
Email:
sales@jinaipu.com
Tel.: 0086-10-82133318 Ext.810
Fax: 0086-10-82118197
Mobile: 0086-18210009838
IMs:
Skype: Gold-APP-Instruments
single and multi point BET surface area analyzer
V-Sorb 4800S surface areaanalyzer introduction
V-Sorb 4800S is developed by Gold APP Instruments for
surface area determination which utilizes static volumetric method.
Compared with other companies’ analyzers, multi pioneered technologies make
instrument’s performance much better, heighten accuracy and consistence of
results, enhance measurement stability, all these lead to a leading level
in world market. Analyzers designed from the user perspective and equipped
with fully automated operation and user-friendly interface make it easy to
learn, imported accessories assure stability and prolong life. Perfect design,
sophisticated production and strict testing guarantee to meet customers’ real
demands. High cost performance of V-Sorb 4800S easily ensure your investment
profits and flexible equipped peripheral can satisfy different users’ requests.
V-Sorb 4800S surface areaanalyzer parameters
Analysis Method: static volumetric nitrogen adsorption principle
Versatility: Adsorption and desorption isotherms, Single and multi-point
BET method, Langmuir surface area, t-plot external surface area analysis,
True density analysis, carbon black STSA etc.
Measuring Ranges: 0.01m2/g to no known upper limit (surface
area)
Accuracy: repeatability errors ≤1%
Vacuum System: V-Sorb unique monolithic manifolds and solenoid valve control
system, greatly reduce the dead volume; improve the adsorbate micro-change
sensitivity; enhance pore size distribution analysis resolution; decrease
connecting points; strengthen sealing performance and prolonged instrument life
Coolant Level Controller: V-Sorb original coolant level control system with
temperature probe, ensure the coolant level unchanged when compares with sample
cells in the whole analysis process, completely eliminate the analysis errors
caused by dead volume change
Control System: programmable solenoid valve system with high integration
and strong anti-interference ability, enhance instrument’s stability
Sample Ports: four samples’ analyzing and four degassing concurrently
Pressure Measurement: imported sectional measuring dual pressure transducer,
notably improve the measuring accuracy at low P/Po point, two transducers’
0-1000Torr (0-133Kpa)
Transducer Accuracy: imported silicon thin film pressure transducer, accuracy
can reach 0.1% of real reading, better than 0.1% of F.S.(full-scale), far
accurate than Pirani resistance vacuum gauge(general error is 10%-15%)
Partial Pressure: P/Po controllable accuracy range is 5x10-6-0.998
Ultimate Vacuum: 4x10-2Pa (3x10-4Torr)
Vacuum Pump: built-in bipolar vacuum pump controlled by patented software
which can auto control pump’s start/stop
Adsorbate Gas: high purity nitrogen(≥99.999%), Ar, Kr, CO2 etc. non-corrosive
gases are optional
Data Acquisition: high-precision and high integration data acquisition
modules, minimal error, strong anti-interference ability
Data Reduction: Windows®-based independent developed Gold APP softwareTM,
perfect versatility, produced full featured and multi-model reports(txt, word,
excel, pdf)
Specifications: Height 22.05 inches (56cm)* Width 20.87 inches (53cm)*Depth
23.62 inches (60cm); 132
pound (60kg)
V-Sorb 4800S surface area
analyzer features
A: Vacuum System
1. Unique
integral manifolds system, decrease connecting points apparently, reduce leak
rate, improve ultimate vacuum.
2.
Modularity design can configure as customer requests, benefits future functions
extension and instrument maintenance.
3. Germany
imported bipolar vacuum pump, low noise, stable working, oil-return prevention;
ultimate vacuum can reach 4x10-2Pa (3x10-4Torr).
B: Control System
1.
Industry used programmable solenoid valve system, strong anti-interference
ability, convenient for installation and uninstallation.
2.
Separated analysis and treatment manifolds can prevent foreign matter to
contaminate manifolds in sample treatment.
C. Measures for Improving Accuracy
1.
Imported silicon thin film capacitive pressure transducer, accuracy can reach 0.1%
of real reading, better than 0.1% of F.S. (full-scale).
2.
0-10Torr (optional) and 0-1000Torr dual pressure transducers, sectional
measurement in pressure range can reduce errors in low vacuum, 0-10Torr silicon
thin film transducer is highly accurate than Pirani resistance vacuum gauge
(general error is 10%-15%).
3.
Unique monolithic manifolds system, decrease connecting points and reduce leak
rate apparently.
4.
Original stepping coolant level control system, ensure the coolant level
unchanged when compares with sample cells in the whole analysis process,
completely eliminate the analysis errors caused by dead volume change.
5.
Pioneered gas outlet and inlet control system can efficiently prevent sample
splash in evacuation and gas inlet process, guarantee clean manifolds and
sample weight unchanged, avoid zero and liner drifting caused by transducer’s
macro-change.
D. Data Acquisition and Reduction
1.
High precision and integration data acquisition module is easy to connect,
minimal errors and strong anti-interference ability; standard 485 communication
mode is good for analyzer’s applications extension and interconnection, can
also conveniently switched to RS232 and USB modes.
2.
Multi calculating methods for data reduction provides all-round sample analysis
options; powerful data archiving and searching system helps a lot for data
management.
V-Sorb 4800S surface area
analyzer application
1.
Super micro powder, nanomaterials, particle and fiber shaped surface area
analysis.
2.
Product quality control for powder materials related corporations.
3.
Research institutes, universities for BET theory teaching.
4.
Full cells, catalysts, additives, adsorbent, ceramics, magnetic materials,
energy storage materials etc.
5.
Other researches concern surface area performance.
Contact info:
Email:
sales@jinaipu.com
Tel.: 0086-10-82133318 Ext.810
Fax: 0086-10-82118197
Mobile: 0086-18210009838
IMs:
Skype: Gold-APP-Instruments
Subscribe to:
Posts (Atom)